The ultrasonic water meter JOOBY JWM is designed for the accurate measurement of cold and hot water consumption in households, apartment buildings, commercial properties, and for the control of technological processes.
Example | Description |
---|---|
JWM2,5-110P-LRIR-Т70 | Nominal flow rate Q3: 2.5 – 2.5 m3/h; 4 – 4 m3/h; 6.3 – 6.3 m3/h. |
JWM2,5-110P-LRIR-Т70 | Installation length: 110 – 110 mm; 130 – 130 mm; 150 – 150 mm. |
JWM2,5-110P-LRIR-Т70 | Material of the hydraulic component: Р – Polymer; |
JWM2,5-110P-LRIR-Т70 | Communication technology: LR – LoRaWAN®; IR – Infrared output pulse for the verification procedure. |
JWM2,5-110P-LRIR-Т70 | Temperature class: T50, T70, T30/T70 – corresponding temperature class; without designation - T30. |
Parameter names | Parameter values | ||
---|---|---|---|
JWM2,5 | JWM4 | JWM6,3 | |
Nominal diameter DN, mm | 15 | 20 | 25 |
Permanent flow rate Q3, m3/h | 2.5 | 4 | 6.3 |
Overload flow rate Q4, m3/h | 3.125 | 5 | 7.875 |
Transitional flow rate Q2, dm3/h\ | 16 | 26 | 40 |
Minimum flow rate Q1, dm3/h | 10 | 16 | 25 |
Sensitivity threshold, dm3/h | 1 | 1.6 | 2.52 |
Disabling transport mode after minimum flow rate, dm3 | 4 | 6 | 8 |
Measurement range R = Q3/Q1 | R250 | ||
Ratio Q2/Q1 | 1.6 | ||
Water temperature class according to EN ISO 4064-1 | Т30, Т50, Т70, Т30/Т70 | ||
Flow disturbance immunity class according to EN ISO 4064-1 | U3, D3 | ||
Counter-indication range, m3 | 999999 | ||
Actual scale interval, m3 | 0.001 | ||
Accuracy class according to EN ISO 4064-1 | 2 | ||
Maximum permissible error for the upper flow rate zone (Q2 ≤ Q ≤ Q4), % | ±2 for temperatures from 0.1 to 30°C ±3 for temperatures greater than 30°C |
||
Maximum permissible error for the lower flow rate zone (Q1 ≤ Q ≤ Q2), % | ±5 regardless of temperature range | ||
Maximum admissible pressure, bar | 16 (МАР16) | ||
Pressure loss class according to EN ISO 4064-1 | Δр 40 | ||
Installation orientation | V and/or H | ||
Backflow | Backflow counting in a separate counter | ||
Ambient temperature, °C | 5 … 55 | ||
Relative humidity, % | 0 … 100 | ||
IP rating according to EN 60529 | IP68 | ||
Climate and environmental requirements class according to EN ISO 4064- | B | ||
Environmental and mechanical requirements class according to the requirements of Directive 2014/32/EU | M1 | ||
Environmental and electromagnetic requirements class according to EN ISO 4064-1 | Е2 | ||
Batteries | 2x integrated 3.6 V DC lithium batteries | ||
Battery lifetime | 16 years | ||
Total average lifetime, years | 15 |
Modulation | LoRa™ Spread-Spectrum class A |
---|---|
Radiation class (NCCIR No. 87) | 250KF1D |
Receiver sensitivity, dBm | -118 … -136 |
Data transfer rate, kbit/s | 0.250 – 11 |
Communication range in line-of-sight conditions, km | Up to 10 |
Communication range in urban areas, km | Up to 2 |
Frequency range, MHz | 868.0 – 868.6 |
Transmitter power, mW(dBm) | 25(14) |
Duty cycle, % | <1 |
Bandwidth, kHz | 125 (62,5, 256) |
Data transfer rate, bits/s | 250 – 50,000 |
Cyclicity of data transmission | Configurable (default once every 4 hours) |
Remote change of data transmission frequency | yes |
Data storage period in non-volatile memory (not less than/max), years | 10/15 |
Capacity of hourly consumption log, months | 3 |
Capacity of daily consumption log, years | 2 |
Capacity of events and alarms log, number of events | 256 |
Battery status monitoring | yes |
Support ADR (Adaptive Data Rate) | yes |
Parameter names | Parameter values | ||
---|---|---|---|
JWM2,5 | JWM4 | JWM6,3 | |
Connection G thread, inch | 3/4” | 1” | 1 1/4” |
Mounting fitting thread, inch | 1/2” | 3/4” | 1” |
Water meter length L, mm | 110 | 130 | 150 |
Water meter height H, mm | 84 | 88 | 92 |
Water meter height from tube axis h, mm | 69 | 69 | 71 |
Width (counter size) D, mm | 95 | ||
Weight, kg | 0.3 | 0.33 | 0.4 |
LCD indications | ||||
---|---|---|---|---|
![]() | LCD view | |||
![]() | Volume indication, m3 | |||
![]() | Flow rate indication, L/h | |||
![]() | Low battery indication | ![]() | Empty pipe indication | |
![]() | Active data transmitting indication | ![]() | Leakage indication | |
![]() | Warning indication | ![]() | Burst indication | |
![]() | Transport mode indication | ![]() | Direct flow direction animation | |
![]() | Reverse flow direction animation | |||
Do not use connection fittings that have a protruding part on the surface adjacent to the water meter, which can penetrate inside the water meter and damage it. Use fittings with a flat abutting surface only. see Fig.