ULTRASONIC WATER METER JOOBY JWM

Jooby Store

Jooby Smart City Devices

Jooby Development

Application

The ultrasonic water meter JOOBY JWM is designed for the accurate measurement of cold and hot water consumption in households, apartment buildings, commercial properties, and for the control of technological processes.

Part numbers

Certificates and downloads

Ordering specification

Example Description
JWM2,5-110P-LRIR-Т70 Nominal flow rate Q3:
2.5 – 2.5 m3/h;
4 – 4 m3/h;
6.3 – 6.3 m3/h.
JWM2,5-110P-LRIR-Т70 Installation length:
110 – 110 mm;
130 – 130 mm;
150 – 150 mm.
JWM2,5-110P-LRIR-Т70 Material of the hydraulic component:
Р – Polymer;
JWM2,5-110P-LRIR-Т70 Communication technology:
LR – LoRaWAN®;
IR – Infrared output pulse for the verification procedure.
JWM2,5-110P-LRIR-Т70 Temperature class:
T50, T70, T30/T70 – corresponding temperature class;
without designation - T30.

Features

Meter specifications

Parameter names Parameter values
JWM2,5 JWM4 JWM6,3
Nominal diameter DN, mm 15 20 25
Permanent flow rate Q3, m3/h 2.5 4 6.3
Overload flow rate Q4, m3/h 3.125 5 7.875
Transitional flow rate Q2, dm3/h\ 16 26 40
Minimum flow rate Q1, dm3/h 10 16 25
Sensitivity threshold, dm3/h 1 1.6 2.52
Disabling transport mode after minimum flow rate, dm3 4 6 8
Measurement range R = Q3/Q1 R250
Ratio Q2/Q1 1.6
Water temperature class according to EN ISO 4064-1 Т30, Т50, Т70, Т30/Т70
Flow disturbance immunity class according to EN ISO 4064-1 U3, D3
Counter-indication range, m3 999999
Actual scale interval, m3 0.001
Accuracy class according to EN ISO 4064-1 2
Maximum permissible error for the upper flow rate zone (Q2 ≤ Q ≤ Q4), % ±2 for temperatures from 0.1 to 30°C
±3 for temperatures greater than 30°C
Maximum permissible error for the lower flow rate zone (Q1 ≤ Q ≤ Q2), % ±5 regardless of temperature range
Maximum admissible pressure, bar 16 (МАР16)
Pressure loss class according to EN ISO 4064-1 Δр 40
Installation orientation V and/or H
Backflow Backflow counting in a separate counter
Ambient temperature, °C 5 … 55
Relative humidity, % 0 … 100
IP rating according to EN 60529 IP68
Climate and environmental requirements class according to EN ISO 4064- B
Environmental and mechanical requirements class according to the requirements of Directive 2014/32/EU M1
Environmental and electromagnetic requirements class according to EN ISO 4064-1 Е2
Batteries 2x integrated 3.6 V DC lithium batteries
Battery lifetime 16 years
Total average lifetime, years 15

Radio transmission and data logging characteristics

Modulation LoRa™ Spread-Spectrum class A
Radiation class (NCCIR No. 87) 250KF1D
Receiver sensitivity, dBm -118 … -136
Data transfer rate, kbit/s 0.250 – 11
Communication range in line-of-sight conditions, km Up to 10
Communication range in urban areas, km Up to 2
Frequency range, MHz 868.0 – 868.6
Transmitter power, mW(dBm) 25(14)
Duty cycle, % <1
Bandwidth, kHz 125 (62,5, 256)
Data transfer rate, bits/s 250 – 50,000
Cyclicity of data transmission Configurable (default once every 4 hours)
Remote change of data transmission frequency yes
Data storage period in non-volatile memory (not less than/max), years 10/15
Capacity of hourly consumption log, months 3
Capacity of daily consumption log, years 2
Capacity of events and alarms log, number of events 256
Battery status monitoring yes
Support ADR (Adaptive Data Rate) yes

Operating conditions

Appearance

  1. Production year;
  2. Date for changing the meter;
  3. Part number;
  4. Measurement range Q3/Q1;
  5. Flow disturbance immunity class;
  6. Maximum pressure;
  7. Pressure loss class and temperature class;
  8. Environmental, mechanical, and electromagnetic requirements classes;
  9. Permanent flow rate;
  10. Serial number;
  11. Manufacturer’s logo;
  12. Communication type;
  13. QR-code;
  14. Manufacturer’s address;
  15. Button;
  16. Manufacturer’s name;
  17. EUI number;
  18. Conformity markings and additional metrology marking;
  19. Instantaneous flow rate indication, L/h;
  20. Total volume, m3;
  21. LCD.

Overall, connecting dimensions and weight

Parameter names Parameter values
JWM2,5 JWM4 JWM6,3
Connection G thread, inch 3/4” 1” 1 1/4”
Mounting fitting thread, inch 1/2” 3/4” 1”
Water meter length L, mm 110 130 150
Water meter height H, mm 84 88 92
Water meter height from tube axis h, mm 69 69 71
Width (counter size) D, mm 95
Weight, kg 0.3 0.33 0.4

Appearance of the meter LCD and description of its symbols and icons

LCD indications
LCD view
Volume indication, m3
Flow rate indication, L/h
Low battery indication Empty pipe indication
Active data transmitting indication Leakage indication
Warning indication Burst indication
Transport mode indication Direct flow direction animation
Reverse flow direction animation

Alarms and events

Installation requirements

Installation

Warning

Do not use connection fittings that have a protruding part on the surface adjacent to the water meter, which can penetrate inside the water meter and damage it. Use fittings with a flat abutting surface only. see Fig.

Activation

Verification

User interface