en:rdc:command_parameter_examples
Table of Contents
Get Parameters
1 - Reporting Data Interval
Send Queue
| HEX | Base64 |
|---|---|
04010151 | BAEBUQ== |
| 04 | Get Parameter |
| 01 | Command Length |
| 01 | TYPE_PARAMETERS=1 PERIOD – значение определяет периодичность отправки данных из датчика |
| 51 | LRC |
Response from Module
| HEX | Base64 |
|---|---|
0405010000000154 | BAUBAAAAAVQ= |
| 04 | Get Parameter |
| 05 | Command Length |
| 01 | TYPE_PARAMETERS=1 |
| 000000 | Reserved |
| 01 | Значение определяется с разрешение в 600 секунд. в Данном случае уже был выставлен параметр в 10 минут. Считается вот так: 600 секунд (это 10 минут) / на 600 секунд (разрешение) = 1 |
| 54 | LRC |
4 - Day checkout hour (Get billing Date)
Send Queue
| HEX | Base64 |
|---|---|
| 04010454 | BAEEVA== |
| 04 | Get Parameter |
| 01 | Command Length |
| 04 | TYPE_PARAMETERS=4 Задание расчетного часа |
| 54 | LRC |
Response from Module
| HEX | Base64 |
|---|---|
| 0402040651 | BAIEBlE= |
| 04 | Get Parameter |
| 02 | Command Length |
| 04 | TYPE_PARAMETERS=4 |
| 06 | 0_HOUR=6 Значение от 0 до 23. По умолчанию расчетный час равен 0 |
| 51 | LRC |
5 - Reporting data type
Send Queue
| HEX | Base64 |
|---|---|
| 04010555 | BAEFVQ== |
| 04 | Get Parameter |
| 01 | Command Length |
| 05 | TYPE_PARAMETERS=5 Тип выдаваемых данных |
| 55 | LRC |
Response from Module
| HEX | Base64 |
|---|---|
| 0402050355 | BAIFA1U= |
| 04 | Get Parameter |
| 02 | Command Length |
| 05 | TYPE_PARAMETERS=5 |
| 03 | DATA_TYPE=3 (3 - данные почасового потребления и данные суточного потребления.) По умолчанию стоит 0 – данные почасового потребления |
| 55 | LRC |
8 - Priority data delivery type
Send Queue
| HEX | Base64 |
|---|---|
| 04010858 | BAEIWA== |
| 04 | Get Parameter |
| 01 | Command Length |
| 08 | TYPE_PARAMETERS=8 TX_DATA – значение определяет способ доставки приоритетных данных |
| 58 | LRC |
Response from Module
| HEX | Base64 |
|---|---|
| 040208015a | BAIIAVo= |
| 04 | Get Parameter |
| 02 | Command Length |
| 08 | TYPE_PARAMETERS=8 TX_DATA – значение определяет способ доставки приоритетных данных |
| 01 | 0 – данные с подтверждением доставки данных, 1 – данные передаются без подтверждения доставки. |
| 5a | LRC |
9 - Activation method
Send Queue
| HEX | Base64 |
|---|---|
| 04010959 | BAEJWQ== |
| 04 | Get Parameter |
| 01 | Command Length |
| 09 | TYPE_PARAMETERS = 9 |
| 59 | LRC |
Response from Module
| HEX | Base64 |
|---|---|
| 040209015b | BAIJAVs= |
| 04 | Get Parameter |
| 02 | Command Length |
| 09 | TYPE_PARAMETERS = 9 |
| 01 | TX_DATA 0 (значение по умолчанию) – OTAA активация через отправку пакета JOIN ; «1» - ABP активация путем записи всех ключей в устройство без формирования и отправки пакета JOIN. По умолчанию OTAA. |
| 5b | LRC |
10 - Battery depassivation info
Send Queue
| HEX | Base64 |
|---|---|
| 04010a5a | BAEKWg== |
| 04 | Get Parameter |
| 01 | Command Length |
| 0a | TYPE_PARAMETERS = 10 (in HEX) |
| 5a | LRC |
Response from Module
| HEX | Base64 |
|---|---|
| 04070a138840000c1c97 | BAcKE4hAAAwclw== |
| 04 | Get Parameter |
| 07 | Command Length |
| 0a | TYPE_PARAMETERS = 10 (in HEX) |
| 1388 | loadTime:5000 |
| 4000 | internalResistance:16384 |
| 0c1c | lowVoltage:3100 |
| 97 | LRC |
11 - Battery minimal load time
Send Queue
| HEX | Base64 |
|---|---|
| 04010b5b | BAELWw== |
| 04 | Get Parameter |
| 01 | Command Length |
| 0b | TYPE_PARAMETERS = 11 (in HEX) |
| 5b | LRC |
Response from Module
| HEX | Base64 |
|---|---|
| 04050b000500005a | BAULAAUAAFo= |
| 04 | Get Parameter |
| 05 | Command Length |
| 0b | TYPE_PARAMETERS = 11 (in HEX) |
| 00050000 | value:327680 |
| 5a | LRC |
18 - RX2 config (RX2_CFG)
Send Queue
| HEX | Base64 |
|---|---|
| 04011242 | BAESQg== |
| 04 | Get Parameter |
| 01 | Command Length |
| 12 | TYPE_PARAMETERS = 18 (in HEX) |
| 42 | LRC |
Response from Module
| HEX | Base64 |
|---|---|
| 040512ffffffff46 | BAUS/////0Y= |
| 04 | Get Parameter |
| 05 | Command Length |
| 12 | TYPE_PARAMETERS = 18 (in HEX) |
| ff | spreadFactor:255 |
| ffffff | frequency:1677721500 |
| 46 | LRC |
22 - DELTA_TIME_EN
Send Queue
| HEX | Base64 |
|---|---|
| 04011646 | BAEWRg== |
| 04 | Get Parameter |
| 01 | Command Length |
| 16 | TYPE_PARAMETERS = 22 (in HEX) |
| 46 | LRC |
Response from Module
| HEX | Base64 |
|---|---|
| 0402160045 | BAIWAEU= |
| 04 | Get Parameter |
| 02 | Command Length |
| 16TYPE_PARAMETERS = 22 (in HEX) | |
| 00 | Значение по умолчанию “0” |
| 45 | LRC |
23 - METER_BASE_DATA
Send Queue
| HEX | Base64 |
|---|---|
| 04011747 | BAEXRw== |
| 04 | Get Parameter |
| 01 | Command Length |
| 17 | TYPE_PARAMETERS = 23 (in HEX) |
| 47 | LRC |
Response from Module
| HEX | Base64 |
|---|---|
| 040617000000000040 | BAYXAAAAAABA |
| 04 | Get Parameter |
| 06 | Command Length |
| 17 | TYPE_PARAMETERS = 23 (in HEX) |
| 0000000000 | METER_BASE_DATA |
| 40 | LRC |
24 - Enable absolute data
Send Queue
| HEX | Base64 |
|---|---|
| 04011848 | BAEYSA== |
| 04 | Get Parameter |
| 01 | Command Length |
| 18 | absolute data state = 24 (in HEX) |
| 48 | LRC |
Response from Module
| HEX | Base64 |
|---|---|
| 040218004b | BAIYAEs= |
| 04 | Get Parameter |
| 02 | Command Length |
| 18 | absolute data state = 24 (in HEX) |
| 00 | absolute data state=0 |
| 4b | LRC |
25 - Serial number
Send Queue
| HEX | Base64 |
|---|---|
| 04011949 | BAEZSQ== |
| 04 | Get Parameter |
| 01 | Command Length |
| 19 | Serial number = 25 (in HEX) |
| 49 | LRC |
Response from Module
| HEX | Base64 |
|---|---|
| 040719ffffffffffff4f | BAcZ////////Tw== |
| 04 | Get Parameter |
| 07 | Command Length |
| 19 | absolute data state = 24 (in HEX) |
| ffffffffffff | Serial number |
| 49 | LRC |
Set Parameters
GET+SET+GET in One Command
en/rdc/command_parameter_examples.txt · Last modified: 2023/06/27 19:05 by joobyadmin